Data
618,887 items of data are available, covering 499,052 participants.
Defined-instances run from 0 to 3, labelled using Instancing
2.
Units of measurement are Kg.
Maximum | 90 |
Decile 9 | 45 |
Decile 8 | 40 |
Decile 7 | 35 |
Decile 6 | 30 |
Median | 28 |
Decile 4 | 24 |
Decile 3 | 22 |
Decile 2 | 20 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 90 distinct values.
- Mean = 29.1053
- Std.dev = 11.2368
- 96 items above graph maximum of 74
|
4 Instances
Instance 0 : Initial assessment visit (2006-2010) at which participants were recruited and consent given
498,739 participants, 498,739 items
Maximum | 89 |
Decile 9 | 46 |
Decile 8 | 40 |
Decile 7 | 36 |
Decile 6 | 32 |
Median | 28 |
Decile 4 | 25 |
Decile 3 | 22 |
Decile 2 | 20 |
Decile 1 | 16 |
Minimum | 0 |
|
|
- There are 86 distinct values.
- Mean = 29.5464
- Std.dev = 11.3278
- 36 items above graph maximum of 76
|
Instance 1 : First repeat assessment visit (2012-13)
20,191 participants, 20,191 items
Maximum | 76 |
Decile 9 | 40 |
Decile 8 | 34 |
Decile 7 | 30 |
Decile 6 | 27 |
Median | 24 |
Decile 4 | 20 |
Decile 3 | 18 |
Decile 2 | 16 |
Decile 1 | 12 |
Minimum | 0 |
|
|
- There are 67 distinct values.
- Mean = 24.9625
- Std.dev = 10.6299
- 4 items above graph maximum of 68
|
Instance 2 : Imaging visit (2014+)
87,897 participants, 87,897 items
Maximum | 90 |
Decile 9 | 42 |
Decile 8 | 38 |
Decile 7 | 32 |
Decile 6 | 30 |
Median | 26 |
Decile 4 | 24 |
Decile 3 | 21 |
Decile 2 | 18 |
Decile 1 | 15 |
Minimum | 0 |
|
|
- There are 83 distinct values.
- Mean = 27.7565
- Std.dev = 10.6221
- 67 items above graph maximum of 69
|
Instance 3 : First repeat imaging visit (2019+)
12,060 participants, 12,060 items
Maximum | 80 |
Decile 9 | 42 |
Decile 8 | 37 |
Decile 7 | 32 |
Decile 6 | 30 |
Median | 26 |
Decile 4 | 24 |
Decile 3 | 21 |
Decile 2 | 19 |
Decile 1 | 15 |
Minimum | 0 |
|
|
- There are 68 distinct values.
- Mean = 27.632
- Std.dev = 10.4518
- 2 items above graph maximum of 69
|
Notes
Left grip strength.
An issue has been identified with the a small amount of grip strength data (
Field 46 and
Field 47) collected in Cheadle during the first repeat visit in 2013 (Instance 1). We are working on modelling a correction factor for this data. In the meantime, researchers are advised to treat the 2013 grip strength data with caution.
In particular, readings from dynamometer 7336 are lower than expected. The mean error is approximately 2 kg for readings taken in January 2013, gradually increasing to a mean error of 14 kg for readings taken in June 2013.
The dynamometer was recalibrated after June 2013, during scheduled yearly external calibration, and there is no evidence of problems with dynamometer 7336 during instances 0, 2 or 3.
2 Related Data-Fields
Field ID | Description | Relationship |
47 | Hand grip strength (right) | Current Field is the opposite-side complement to Field 47 |
20044 | Reason for skipping grip strength (left) | Field 20044 gives reasons for skipping measurement Current Field |